Contact

VAR.P in SoftMaker PlanMaker: Population Variance and Squared Units

Statistical Intermediate SoftMaker PlanMaker

Use VAR.P in SoftMaker PlanMaker with three worked numeric examples, CSV practice data, interpretation checks, and software-specific documentation notes.

Verification status: See the evidence and test scope described in this guide. How formula examples are checked

Availability and version history

  • Introduced: Documented by the PlanMaker 2018 manual; the original introduction version and date are not established.
  • Availability: Documented in PlanMaker 2026. This is a supported-version reference, not a final working-version endpoint.
  • Scope: The reference belongs to the 2026/NX manual family; availability in FreeOffice and individual mobile builds is not established here.
  • Checked: October 14, 2026, against the official function reference. Documentation and independently calculated examples; no native test of these cases.

Quick answer

Use VAR.P in SoftMaker PlanMaker to calculate the variance of a complete population, dividing the sum of squared deviations by n. The working example below describes weekly dispatch quantities; its result is measured in squared boxes. The official reference supports the function’s identity and purpose.

Syntax and arguments

=VAR.P(Number1, Number2 [, Number3 ...])

The official printed signature has two leading inputs. Each can be a value, range or array. These range-based examples use two disjoint ranges, following that notation without assuming an omitted second argument. Several observations can occupy each range; argument count and observation count are different.

Additional inputs are optional. Omit the notation’s brackets when entering a formula. The examples use numeric observations and the English help’s comma separator. Single-range acceptance is not assessed here.

When this calculation is useful

Use population variance to describe the spread of every observation in a specifically defined population. It gives equal weight to each included numeric observation. A row containing a subtotal is not interchangeable with a row containing an individual observation; mixing those two levels changes the question.

Variance is in squared units. It becomes one hundred times larger when every observation is multiplied by ten, even though the underlying pattern is unchanged. This makes it useful in calculations but easy to mislabel in a dashboard. Use a matching standard deviation measure when readers need a spread expressed in the original units.

Set up the practice data

A desktop dispatch workbook with one row per completed week provides the scenario. Enter the following numeric observations into A2:A7, one per row, with a header in A1. Use H2:H4 for the three result formulas, outside the input and CSV fields.

Cell Boxes
A2 3
A3 5
A4 7
A5 5
A6 9
A7 11

Download the SoftMaker PlanMaker VAR.P practice data (CSV). Import it into a new, blank sheet starting at A1, with a comma as the file delimiter and the header row retained. The CSV contains input values only, not formulas or native test results. The extra test values occupy F2:F5. The CSV also has record IDs in B and an unused RequestedPosition field in D. Do not count those fields as observations. Keep observations numeric rather than importing them as text.

Three worked examples

Example 1: Measure spread in the working register

Enter in H2:

=VAR.P(A2:A4,A5:A7)

Expected result: 7.222222 (displayed to six decimal places).

The numeric count is 6, the mean is 6.666667, and the sum of squared deviations is 43.333333. Divide by 6 (n); the result is a variance in squared measurement units.

Example 2: Check the denominator with three known numbers

Enter in H3:

=VAR.P(2,4,6)

Expected result: 2.666667 (displayed to six decimal places).

The mean is 4 and the squared deviations are 4, 0 and 4, for a total of 8. The population denominator is 3.

Example 3: Check squared units when values are rescaled

For this check, use F2:F5 containing 0, 0, 80, 80, in that order. These values are included in the practice file.

Enter in H4:

=VAR.P(F2:F3,F4:F5)

Expected result: 1600.

These four observations have mean 40 and squared deviations totalling 6400. They are ten times the numbers 0, 0, 8, 8, so their variance is one hundred times as large. Both zeros still count as observations.

Advanced: reconstruct the result from individual deviations

Preserve A:F. Put Observation, Deviation and Squared deviation in J1:L1. Enter =AVERAGE(A2:A7) in N2; expect 6.6666666667, displayed here to ten decimal places. In J2 enter =A2, K2 =J2-$N$2 and L2 =K2^2. Fill J2:L2 through row 7.

Row Expected K, approximately Expected L, approximately
2 -3.6666666667 13.4444444444
3 -1.6666666667 2.7777777778
4 0.3333333333 0.1111111111
5 -1.6666666667 2.7777777778
6 2.3333333333 5.4444444444
7 4.3333333333 18.7777777778

In N3 enter =SUM(L2:L7); expect approximately 43.3333333333. Put 6 in N4, the number of observations in this complete fixture, and enter =N3/(N4) in N5. Expect approximately 7.2222222222, matching H2 before display rounding. Keep the calculated mean in N2 at full stored precision; do not replace it with rounded text from the table.

Enter =VAR.S(A2:A4,A5:A7) in N7 and =N5*6/5 in N8. Both targets are approximately 8.6666666667. The conversion compares the same six observations with different denominators; it does not combine variances from unrelated groups.

For a shift control, put =A2+100 in P2 and fill through P7. Enter =VAR.P(P2:P4,P5:P7) in R2. Its target remains approximately 7.2222222222: adding a fixed amount shifts the mean by that amount but leaves every deviation unchanged.

On a separate VendorCheck sheet, put =VAR.P(2,2,3,4,1) in A1. The reference displays 1.04. The mean is 2.4 and the squared deviations sum to 5.2, so the population divisor is 5.

Common mistakes and troubleshooting

The output is labelled with ordinary units. A variance of 16 from data in minutes is 16 minutes squared. Its square root, 4, is the population standard deviation in minutes.

The result changes after rescaling the data. That is expected: multiplying each input by a factor multiplies variance by the square of that factor. Merely changing display formatting, without changing stored values, is a different operation.

The range includes summary rows or missing-value replacements. A subtotal introduces an extra observation, and replacing an unknown value with zero invents a measurement. Define the inclusion rule and inspect the data before relying on the resulting variance.

PlanMaker input rules and compatibility

The current reference distinguishes referenced cells from directly supplied arguments. Referenced empty cells, error cells, text and logical values are ignored. Direct text and logical arguments can be included, but the entry does not fully define every conversion. These numeric fixtures avoid relying on those boundaries. An ignored source error still deserves investigation; it is not evidence that the underlying record is valid.

The current VARP entry identifies VAR.P as an identical supplemental function. Both names remain documented; the presence of a dotted name does not establish retirement of the older one. Its Excel 2010 compatibility note concerns Excel, not PlanMaker’s introduction release.

The 2018 manual gives the same printed argument structure and numeric example. Its shorter mixed-data wording is not a native behavior test of that older build. Exact error tokens, single-observation population handling and conversion/precision limits remain unverified here. Use complete numeric observations and retain original data when comparing programs.

For the same statistical question in other programs, see VAR.P in Microsoft Excel, VAR.P in Google Sheets, VAR.P in ONLYOFFICE. These links identify corresponding measures, not a guarantee that names, mixed-data rules, error codes or file conversions are identical.

MEDIAN, LARGE, SMALL, RANK.EQ, STDEV.S, STDEV.P, VAR.S. Browse the SoftMaker PlanMaker function library for the other published guides.